Fire Alarm · Fire Pump · Fire Suppression FM200 NOVEC IG100 NN100

Fire Alarm Creator — design, installation, maintenance and certification of firealarm and firepump systems to NFPA standards
Fire Alarm Creator Co., Ltd. — authorised distributor of Notifier, Edwards, Nohmi, Siemens, System Sensor, Kidde, Tyco, Viking
PM fire pump NFPA 25 performance test — fire pump engine and pump repair Thailand
Design, installation, inspection, testing and maintenance of firealarm firepump firesuppression systems
12+
Years of experience
500+
Projects completed
NFPA
International standard
24/7
Ready to serve

Complete fire protection specialists

Maintenance is the heart of safety

Fire Alarm Creator Co., Ltd. provides firealarm (fire alarm systems), firepump (fire pump systems) and firesuppression — automatic clean agent suppression with FM200, NOVEC 1230, IG100 and NN100 — covering everything from site survey and design to installation, testing and engineer certification.

All work follows NFPA 72, NFPA 25, NFPA 2001 and the standards of the Engineering Institute of Thailand (EIT), certified by electrical and mechanical engineers licensed by the Council of Engineers.

About us

Complete fire protection services

Full scope of work and applicable standards for each system

Fire alarm system firealarm Notifier EST Edwards Thailand
FIRE ALARM SYSTEM

Fire alarm systems

Maintenance, testing and inspection of firealarm systems to NFPA 72, with certification reports signed by a licensed electrical engineer.

  • Preventive maintenance (PM), monthly and annual
  • Performance testing to NFPA 72
  • Certification reports for building inspectors
  • Supply of Notifier, EST Edwards, Siemens, Nohmi
View details
Fire pump system firepump NFPA 25 Thailand
FIRE PUMP SYSTEM

Fire pump systems

Engine and pump repair, pressure and performance testing to NFPA 25, certified by a licensed mechanical engineer.

  • Engine repair — Cummins, John Deere, Caterpillar
  • Fire pump repair, all sizes and brands
  • Water pressure and NFPA 25 performance tests
  • PM plans — weekly, monthly, quarterly, annual
View details
Automatic fire suppression firesuppression FM200 NOVEC IG100 NN100
FIRE SUPPRESSION

Automatic fire suppression

firesuppression with clean agents FM200, NOVEC 1230, IG100 and NN100 for server rooms, data centres and electrical rooms.

  • FM200 (HFC-227ea) and NOVEC 1230 (FK-5-1-12)
  • IG100 (nitrogen) and NN100 inert gas
  • Design and installation to NFPA 2001
  • Maintenance, cylinder weighing and agent refill
View details

Choose the right agent for your space

Each clean agent has different properties — see the technical detail of each system

HFC-227ea

FM200

The most widely used clean agent. Discharges within 10 seconds and needs little cylinder storage space — ideal for small to medium server rooms.

View details
FK-5-1-12

NOVEC 1230

Very low GWP and environmentally friendly. Stored as a liquid at atmospheric pressure and safe for electronic equipment.

View details
Nitrogen 100%

IG100

Pure nitrogen that leaves no residue and has zero ozone impact — suited to large rooms and industrial areas.

View details
Nitrogen clean agent

NN100

A nitrogen system for spaces that need a non-conductive agent that is safe for both people and assets.

View details

Experience & reliability

Trusted by leading public and private organisations across Thailand

01

Licensed for controlled engineering practice

Licensed by the Council of Engineers under the Engineers Act B.E. 2542 (1999); work is certified by electrical and mechanical engineers.

02

Serving leading state organisations

Trusted to maintain firealarm and firepump systems for MEA, PEA, EGAT, CAT and NT.

03

NFPA & EIT standards

Every job follows NFPA 72, NFPA 25, NFPA 2001 and the standards of the Engineering Institute of Thailand.

04

Cummins & John Deere engine repair

Technicians specialised in firepump engines, including overhaul and replacement of filters, belts and injectors.

05

Certification reports for building inspectors

Complete testing and certification reports for the legally required annual building inspection.

How we work

The same standard process on every project

01

Survey & assess

Engineers visit the site, inspect existing systems and assess requirements.

02

Design & quotation

Design to NFPA/EIT standards with shop drawings and a detailed quotation.

03

Execute & test

Maintenance, installation or system testing by specialist technicians.

04

Certify & hand over

Engineer certification report with a complete document set for authority submission.

Our clients

Trusted by leading organisations across Thailand

Utilities & energy (state enterprises)
การไฟฟ้านครหลวง MEA — Fire Alarm Creator clientการไฟฟ้าส่วนภูมิภาค PEA — Fire Alarm Creator clientการไฟฟ้าฝ่ายผลิต EGAT — Fire Alarm Creator clientCAT Telecom — Fire Alarm Creator clientNT National Telecom — Fire Alarm Creator client
Industry & leading companies
PTT — Fire Alarm Creator clientSCG — Fire Alarm Creator clientCPRAM — Fire Alarm Creator clientBridgestone — Fire Alarm Creator clientBetagro — Fire Alarm Creator clientElectrolux — Fire Alarm Creator clientNestle — Fire Alarm Creator clientBITEC — Fire Alarm Creator client
Hotels & retail
Millennium Hilton Bangkok — Fire Alarm Creator clientRoyal Orchid Sheraton — Fire Alarm Creator clientThe Westin Grande Sukhumvit — Fire Alarm Creator clientHua Hin Grand Hotel — Fire Alarm Creator clientSynphaet Hospital — Fire Alarm Creator clientJaymart — Fire Alarm Creator clientThe Walk Ratchaphruek — Fire Alarm Creator clientSingha — Fire Alarm Creator client

Free consultation

By our engineers and specialists — reply within 24 hours

World-class brands

Notifier by Honeywell fire alarm — authorised distributor ThailandEST Edwards fire alarm — authorised distributor ThailandSiemens fire safety — authorised distributor ThailandNohmi Bosai — authorised distributor ThailandSystem Sensor — authorised distributor ThailandKidde Fire Systems FM200 NOVEC — authorised distributor ThailandTyco sprinkler — authorised distributor ThailandViking — authorised distributor Thailand

See our work in action

Watch our engineers and technicians on real projects

Frequently asked questions

How often should a firealarm system be inspected?
NFPA 72 recommends testing detection and notification devices at least once a year, while control panels and batteries should be checked every 3-6 months to keep the system ready and reduce false alarms.
What does an NFPA 25 firepump test involve?
NFPA 25 requires a no-flow churn test weekly or monthly depending on the driver, plus a full annual flow test measuring pressure and flow at shutoff, rated and overload points, plotted against the pump curve.
What is the difference between FM200 and NOVEC 1230?
FM200 (HFC-227ea) needs less cylinder storage space and costs less to install, while NOVEC 1230 (FK-5-1-12) has a very low GWP and a short atmospheric lifetime, making it far more environmentally friendly. Both are clean agents that leave no residue and are safe for electrical equipment.
Where are IG100 and NN100 best used?
Both are nitrogen systems suited to large rooms, generator rooms and industrial areas that need an agent leaving no residue and causing no ozone depletion. They extinguish fire by reducing the oxygen level in the room.
Do you issue engineer certification reports?
Yes. Our licensed electrical and mechanical engineers issue inspection and certification reports for firealarm, firepump and firesuppression systems, for submission at the annual building inspection.